Technical Name Intelligent In Situ Monitoring of Membrane Fouling
Project Operator National Taiwan University
Project Host 童國倫
Summary
This technology uses in-situ optical photointerrupt sensorin-situ acoustic ultrasonic transducer to measure the growth of fouling layer thickness during membrane water treatment. Being the world’s first to combine real-time filter speed attenuation dataphysical mode of clogging, the clogging of film can be instantly analyzed in a smart way which in turn effectively extends its lifetime. T
Scientific Breakthrough
"An integrated technique for online fouling monitoring with process-oriented capacities of:
1. in situ measurement of fouling layer thickness
2. dynamic analysis of fouling layer structure
3. monitoringpredicting membrane fouling potential
The analysis of its real-time changes can optimize appropriate cleaning parametersoperating conditions for subsequent operations thus reducing various
Industrial Applicability
By replacing traditional wastewater treatment process with membrane separation technology, high separation efficiencygood quality of discharged water can be achieved. However, the biggest challenge faced in the developing this technology is the fouling of membrane. When membrane fouling occurs, the filtration rate will significantly reduce which in turn increasing the operation costs. With re
Keyword Water and wastewater treatment Membrane filtration On-line monitoring In-situ monitoring Optical method Acoustic method LED photointerrupt sensor ultrasonic transducer Artificial intelligent Water reuse
Notes
  • Contact